Configuring Alert Settings
Last updated
Last updated
There are a number of options available for email alerts to be sent when certain network or device events occur.
Alerts can be configured under Configure > Alerts.
Alerts can be configured for the following access point events:
AP(s) go offline for XXX minutes: sends an email if one or more access points go offline for a preset (and customizable) amount of time.
When new firmware is released, send an email notification before the scheduled firmware upgrade: send an email when new firmware is released before the scheduled firmware upgrade happened.
Configuration changed within the network: sends an email if SSID, radio settings, firmware upgrade, or individual device settings override the default settings.
Alerts can be configured for the following switch events:
Configuration changed within the network: sends an email if SSID, radio settings, firmware upgrades, or individual device settings override the default settings.
When new firmware is released, send an email notification before the scheduled firmware upgrade: send an email when new firmware is released before the scheduled firmware upgrade happened.
Switch port link status change: sends an email when device port link status is changed.
Switch STP Port status change: sends an email when device port STP status is changed.
Switch LBD Port status change: sends an email when device LBD status is changed.
Switch(s) go offline for XX minutes: sends an email when switches go offline for a preset number of minutes.
Any/specific switch port(s) changed link speed: sends an email when a switch port link speed changes.
Alerts can be configured for the following EnGenius Gateway events:
Gateway goes offline for (x) minutes: Sends an email if the gateway is unreachable from the Cloud for the configured number of minutes. Please note that the gateway may still be functioning, this only indicates that it is unable to contact the Cloud
When new firmware is released, send an email notification before the scheduled firmware upgrade: send an email when new firmware is released before the scheduled firmware upgrade happened.
The DHCP lease pool is exhausted: Which Indicates that the gateway has run out of available IPs in one or more of its configured DHCP scopes and is unable to provide an IP address to a requesting client.
A VPN connection comes up or goes down: Send an email if the VPN connection comes up or goes down.
The primary uplink status changes: Send an email if the status of the primary uplink changes, which could be a failover event or a downed link.
Gateway clients connect or disconnect from the LAN: Send an email if the gateway client connects or disconnects from the LAN.
Alerts can be configured for the following PDU events:
PDU goes offline for (x) minutes: Sends an email if the PDU is unreachable from the Cloud for the configured number of minutes. Please note that the PDU may still be functioning, this only indicates that it is unable to contact the Cloud
When new firmware is released, send an email notification before the scheduled firmware upgrade: send an email when new firmware is released before the scheduled firmware upgrade happened.
Overall Power safe ranges: send an email when the PDUs in the network has out of the power safe range.
Overall Current safe ranges: send an email when the PDUs in the network has out of the amp safe range.
Individual outlet out of amp safe range: send an email when the outlets in the network have out of the amp safe range.
Individual PDU out of voltage safe range: send an email when the outlets in the network have out of the voltage safe range.