LogoLogo
  • About Release Notes
  • Cloud Platform
  • Access Point Firmware
    • ECW536
    • ECW526
    • ECW516L
    • ECW336
    • ECW270
    • ECW260
    • ECW230S
    • ECW230v3
    • ECW230
    • ECW220S
    • ECW220v3
    • ECW220v2
    • ECW220
    • ECW215
    • ECW212L
    • ECW210L
    • ECW201L
    • ECW160
    • ECW130
    • ECW120
    • ECW115
  • Switch Firmware
    • ECS15XX/ECS25XX Series
    • ECS5512F/ECS5512FP/ECS5512
    • ECS1008P/ECS1112FP
  • SD-WAN Gateway Firmware
    • ESG510
    • ESG610
    • ESG620
    • ESG320
  • PDU Firmware
    • ECP106/ECP106-INT
    • ECP214/ECP212-INT
  • Switch Extender Firmware
    • EXT1105P
    • EXT1106
    • EXT1109P
  • Camera Firmware
    • ECC100
    • ECC120
  • Cloud To-Go Mobile App
    • v1.5x
    • v1.4x
    • v1.3x
    • v1.2x
    • v1.1x
  • EnGenius Private Cloud (EPC)
Powered by GitBook
On this page
  • v1.0.25
  • [New Features]
  • v1.0.20
  • [New Features]
  • v1.0.15
  • v1.0.10
  • v1.0.7
  • v1.0.5
  • v1.0.0

Was this helpful?

Export as PDF
  1. PDU Firmware

ECP214/ECP212-INT

v1.0.25

[New Features]

  • The Support Rollback Configuration feature allows devices to revert to the previous configuration in case of disconnection caused by an incorrect configuration pushed from EnGenius Cloud.

  • For easier troubleshooting, add a Ping Failed event log for the AutoReboot feature.

  • Enhance the Never Power Off feature: when Never Power Off is enabled, AutoReboot and Schedule cannot be enabled (local GUI only).

v1.0.20

[New Features]

  • Support the new model ECP212-INT.

  • Support enable/disable HTTPs-only for local web page access. Allowing users force web UI access encrypted for better security.

  • Support enable/disable Local Web Page. Allowing users forbid local managements to prevent the confliction with the central cloud management.

  • Add Retry and Reset options to AutoReboot, increasing the flexibility of device power management.

  • Support synchronize "Schedule" configurations in local GUI to Cloud when PDU first time check in Cloud.

  • Add a new event log when PDU detects outlet has no power supply after AutoReboot.

  • Add new event logs for firmware upgrade.

  • Configurations made via LCD will be kept even device reboot.

  • Support displaying the Serial Number and Local Web Page on/off status on the LCD.

v1.0.15

  • Provide email notification in case the connected device loses power from Auto-rebooting.

v1.0.10

  • Improved the voltage safe range to accommodate varying default settings across different countries.

v1.0.7

  • Fixed the issue to let event log record AMP safe range when exceeding configuration range.

  • Fixed the issue to let event log record the configured safe range of power and current.

  • Fixed the issue to correct the testing email's sending errors.

v1.0.5

  • Extend Outlet and User Name Length to 64.

  • Add org license function.

  • Modify default max amp current from 4A to 12A.

  • Add schedule time slider in local GUI page.

v1.0.0

  • This f/w version is for the first release.

PreviousECP106/ECP106-INTNextSwitch Extender Firmware

Last updated 4 months ago