LogoLogo
  • Cloud7 2x2x2
  • Appendix
    • Technical Support
    • Security Bulletin
    • Compliance
    • Declaration of Conformity
    • Disclaimer/ Note
Powered by GitBook
On this page
  • Introduction
  • Package Contents
  • System Requirements
  • Mobile App:
  • Web Browser:
  • Network Requirements
  • Hardware Overview
  • Ports
  • LEDs
  • Hardware Mounting
  • Ceiling Mount
  • Dual Mount
  • Configure with EnGenius Cloud
  • Step1: Register Device and Assign to Network
  • Step2: Power On Device
  • Step3: Connect to the EnGenius Cloud
  • Step4: Manage with the EnGenius Cloud
  • Troubleshooting
Export as PDF

Cloud7 2x2x2

Cloud Managed Wi-Fi 7 2x2x2 Indoor Access Point (ECW526)

Last updated 10 months ago

Introduction

This Quick Start Guide is designed to guide you through the installation of the Cloud7 2x2x2 Access Point, model ECW526, including hardware mounting and configuration.

Cloud7 2x2x2

Cloud Managed Wi-Fi 7 2x2x2 Indoor Access Point

Model: ECW526

  • Wi-Fi 7 technology for high-performance Wi-Fi in high-density, multi-device environments.

  • Supercharged speeds up to 5,800 Mbps on 6 GHz, 2,900 Mbps (5 GHz), and up to 700 Mbps (2.4 GHz).

  • 10 GbE realizes greater throughput and supports 802.3at and 60W PoE injector input for flexible installation over 100 meters (328 feet).

Content Quick Links

Package Contents

System Requirements

The EnGenius Cloud is primarily accessible with a web browser or mobile app. Before signing up for the EnGenius Cloud Service or logging on to the EnGenius Cloud Platform to manage your network, ensure that downloaded the right app and use the supported browser.

Mobile App:

EnGenius Cloud To-Go (iOS/ Android supported)

Web Browser:

  • Google Chrome (57.0.2987.110 and later)

  • Microsoft Edge (80.0.361.103 and later)

  • Mozilla Firefox (52.0 and later)

Network Requirements

Before you get started, please make sure your network environment is DHCP-enabled. EnGenius Cloud Access Points (ECW series) are default assigned an IP address dynamically by the DHCP server.

Hardware Overview

Ports

Reset Button:

  • Reset to default: Press and hold the reset button for over 10 seconds, and the LED(PWR) will start Fast Flashing (0.2 sec). Then, the device will be reset to factory default settings.

LEDs

Hardware Mounting

The access point can be mounted on the Ceiling and Wall. Please perform the steps for the appropriate installation:

Ceiling Mount

  1. Use the outermost screw hole of the Bracket to mark the distance where the T-bar should be fixed on the T-rail.

  2. Loosen the fixed screws on the T-bar with an L-wrench. Align the center screw hole of the T-bar with the position just marked on the T-rail, then tighten the fixed screws on the T-bar using the L-wrench.

  3. Use the Short Screws from the accessory to fix the Bracket onto the T-bar.

  4. Mount the Access Point on the Mounting Bracket by rotating the unit clockwise about 45 degrees to secure it in place.

Dual Mount

1. Determine where the Access Point will be placed and attach the Mounting Bracket to the Wall/ Ceiling using the provided Mounting Kit.

2. Mount the Access Point on the Mounting Bracket by rotating the unit clockwise about 45 degrees to secure it in place.

Configure with EnGenius Cloud

Step1: Register Device and Assign to Network

You can register the device either by the Cloud To-Go mobile app or the EnGenius Cloud platform.

Cloud To-Go Mobile App

  1. Open and log in to the EnGenius Cloud To-Go mobile app.

  2. Scan the QR code on the back of the device via the app.

3. If the camera successfully scans a QR code, the app will display the device Information. You can tap "Register" to complete the Registration.

4. Registered devices will be shown on the Inventory&License page. Slide left the device and click "Add to Network". Add the device to your personalized Network.

Network: Management domain shared same configurations within EnGenius Cloud.

EnGenius Cloud Platform

  1. Go to the home > Inventory&License page and click "Register Device".

4. Select the registered device and click "Assign to Network" to add the device to your personalized Network.

Network: Management domain shared same configurations within EnGenius Cloud.

Step2: Power On Device

The EnGenius Cloud AP devices can be powered by any of the following:

  • EnGenius Cloud PoE Switch or 802.3af/ 802.3at PoE+ compliant Switch

  • EnGenius PoE adaptor (EPA5006GP/EPA5006GAT)

  • Power Adapter (DC 12V/2A power input)

Do not use both power sources at the same time.

Connecting to a PoE Switch

Connect the Ethernet cable from the EnGenius Cloud AP directly to the PoE port of the PoE switch.

Powered with a PoE Adapter

(A) Connect one end of the Ethernet cable into the LAN (PoE) port of EnGenius Cloud AP and the other end to the PoE port on the PoE Adapter.

(B) Connect the power cord with the PoE Adapter and plug the other end into an electrical outlet. (C) Connect the second Ethernet cable into the LAN port of the PoE Adapter and the other end to the Ethernet port on the computer.

Please ensure to use cat5/cat5e UTP/STP RJ45 Ethernet cables.

Powered with a Power Adapter

Connect the Power Cord to the adapter, and then plug the Power Cord into the power outlet.

Step3: Connect to the EnGenius Cloud

Once the device is powered on and ready to connect to the Internet, the LED indicator will stay Solid On, which means the device is now connected to the EnGenius Cloud Platform. It will automatically download the default configuration settings from EnGenius Cloud for automated provisioning.

When the Access Point is connected to the EnGenius Cloud Platform for the first time, it will automatically check the latest firmware version available. If the firmware upgrade is required, it might take 8-10 minutes to complete. The LED indicator will be Flashing (0.5 sec) untill the process is finished.

Step4: Manage with the EnGenius Cloud

Troubleshooting

If the EnGenius Cloud Platform cannot manage your AP, there might be a problem with connecting to EnGenius Cloud.

To troubleshoot the connection issue, you may log in to the Device Local Access page:

  1. Use your client device (e.g., a laptop, mobile device, or tablet) to find the SSID: "EnMGMTxxxx" (xxxx is the last four digits of MAC - MAC would be found on the back of the device) and connect to it.

  2. You can review the device status after logging into the AP with the default admin account/password (admin/admin).

  3. Check the information on Network Connectivity and take action if necessary.

Change IP Assignment Settings

By default, the EnGenius Cloud Access Point (ECW series) is assigned an IP address dynamically by the DHCP server. If you encounter issues with IP address assignment, please double-check the IP setting, including IP address, subnet mask, gateway, proxy, and management VLAN. If the issue still exists, you may change your IP assignment from "DHCP mode" to "Static IP" via the following procedure.

  1. Go to the Local Setting section.

  2. Change IPv4 settings to "Use Static IP".

  3. Configure the IP address, gateway, subnet mask, and proxy settings.

  4. Reconnect this device to the LAN network and try again.

If you encounter issues with IP address assignment, you may want to change your IP assignment from "DHCP mode" to "Static IP". Please check the "" for more details.

Log in to the EnGenius Cloud Platform: .

Enter the Serial Number of the device(s) for device registration. Please refer to "".

Log in to the platform to configure detailed settings. For more information, please refer to .

Under your web browser, enter the URL or http://192.168.1.1 to access the device's user interface.

For more details, please refer to the "".

⬇️
Download the Cloud To-Go mobile app here
User Manual: Login to Local Access Page
https://cloud.engenius.ai/
User Manual-Registering Devices to Organization
EnGenius Cloud
User Manual
http://EnGenius.local
User Manual-Troubleshooting ECW AP
Hardware Overview
Hardware Mounting
Configure with EnGenius Cloud
Scan QR-code for device registration
Device registration
Assign device to a managed Network
Register device(s) with device's Serial Number
Assign selected device(s) to a managed Network
AP is powered by a PoE Switch
AP is powered with a power adapter
EnGenius Cloud Dashboard
ECW AP's Local Access Page
Page cover image