Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
This device complies with Part 15 of FCC rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference received, including interference that may cause undesired operations.
WARNING!
Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his/her own expense.
This device complies with the essential requirements and other relevant provisions of the directives 2004/108 / EC (EMC); 2014 / 30 / EU (EMC); 2006/95 / EC (LVD); 2014/35 / EU (LVD). The following test methods have been applied in order to prove the presumption of conformity with the essential requirements:
EN 55035: 2017/A11:2020
EN 55032:2015+AC:2016, Class A
EN 55024:2010+A1:2015
EN 61000-3-2:2014
EN 61000-3-3:2013
EN 61000-4-2:2008
EN 61000-4-3:2006 +A1:2008 +A2:2010
EN 61000-4-4:2012
EN 61000-4-5:2014 / AMD1:2017
EN 61000-4-6:2013
EN 61000-4-8:2009
EN 61000-4-11:2004 / AMD1: 2017
EN 62368-1:2014+A11:2017
NOTICE:
The operation of this equipment in a residential environment may cause radio interference.
The following information applies if you use the product within Canada.
Industry Canada ICES Statement:
CAN ICES-003 (Issue 6)
The ECS2512FP can be installed on the rack. Please perform the steps to install:
Attach the Mounting Brackets as below and fasten the brackets using the eight Bracket Screws.
2. Secure the Mounting Brackets to the rack using the Mounting Screws.
Connect the Power Cord to the back of the Switch, and then plug the Power Cord into the power outlet.
Hereby, EnGenius Networks declare that this product is in compliance with:
Directives 2004/108 EC (EMC); 2014/30/EU (EMC); 2006/95/EC (LVD); 2014/35/EU (LVD)
RoHS Directive 2015/863
WEEE Directive 2012/19/EU
REACH Regulation
Maximum data rates are based on the IEEE standards. Actual throughput and range may vary depending on many factors including environmental conditions, the distance between devices, radio interference in the operating environment, and the mix of devices in the network.
Features and specifications are subject to change without notice.
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Trademarks and registered trademarks are the property of their respective owners. For the United States of America: Copyright © 2023 EnGenius Technologies, Inc. All rights reserved.
Connect your computer to the switch and ensure its IP address is in the same subnet.
2. Launch your web browser and enter the URL: http://192.168.0.239 to access the switch's local web GUI.
3. Use the default login credential (ID/PWD: admin/password) to log in to the switch's local web page.
After logging in to the device's local web page, navigate to the left-side menu to configure and manage the switch accordingly.
For information on configuring the switch and using the Standalone Configuration, refer to the user guide: https://docs.engenius.ai/ecs-user-manual
EnGenius Cloud devices support versatile network management methods, but the device can only be managed under one management mode, either Cloud To-Go app or Standalone. Therefore, you need to reset the device before changing to a different management mode, followed by QSG instructions for onboarding the device.
EnGenius Cloud To-Go provides flexibility to manage your devices based on your network planning and deployment.
Option A: Cloud Management
Option B: Standalone Configuration
Manage and monitor the switch through the EnGenius Cloud To-Go with a mobile app or through the web portal.
EnGenius Cloud To-Go (iOS/Android)
Download the Cloud To-Go mobile app here
You can locate the computer, connect to the same network (subnet) as the switch and use the web browser to access the device's local web GUI page for configurations whenever the device is in Standalone mode.
Cloud Managed 8-Port 240W PoE++ Multi-Gigabit 2.5 Gb Switch with 4 x SFP+ Uplink Ports(ECS2512FP)
This Quick Start Guide is designed to guide you through the installation of the CloudSwitch MGPlus 8 Full PoE, model ECS2512FP, including hardware installation and configuration.
8 x 2.5 G PoE++ Ports to unleash elevated speeds for NAS, workstations or WiFi 6 APs.
4 x Dual-Speed 10G SFP+ (fiber) uplink ports to high-speed NAS and servers for a high-performance network.
Google Chrome (57.0.2987.110 and later)
Microsoft Edge (80.0.361.103 and later)
Mozilla Firefox (52.0 and later)
Reset to default: Press and hold for over 10 seconds, and all ports LED will go off and on. Then the device will be reset to factory default settings.
Change LED display mode: Press the button to change the LED mode to display the PoE status of PoE-abled ports.
You can register the device either by Cloud To-Go mobile app or the EnGenius Cloud platform.
You can register the switch with the Cloud To-Go app.
Open and log in to the EnGenius Cloud To-Go mobile app.
Scan the QR code on the back of the device via the app.
3. If the camera successfully scans a QR code, the app will display the Device Information. You could tap "Register" to complete the Registration.
4. Registered devices will be shown on the Inventory&License page. Slide left the device and click "Add to Network" add the device to your personalized Network.
Network: Management domain shared same configurations within EnGenius Cloud.
Login into the EnGenius Cloud Platform: https://cloud.engenius.ai/
Go to the home > Inventory page and click "Register Device".
Enter the Serial Number of the device(s) for device registration. Please refer to "User Manual-Registering Devices to Organization".
4. Select the registered device and click "Assign to Network" to add the device to your personalized Network.
Network: Management domain shared same configurations within EnGenius Cloud.
Connect an Ethernet cable from your DHCP-enabled network to any port of EnGenius Cloud Switch.
Once the device is powered on and ready to connect to the Internet, It will automatically download the default configuration settings from EnGenius Cloud for automated provisioning.
When the Switch is connected to the EnGenius Cloud Platform for the first time, it will automatically check the latest available firmware. If the firmware upgrade is required, it might take 8~10 minutes to complete the process.
Log in to the EnGenius Cloud Platform to configure detailed settings. For more information, please refer to User Manual.
If your Switch cannot be managed by the EnGenius Cloud Platform, there might be a problem with connecting to EnGenius Cloud.
To troubleshoot the connection issue, you may log in to the Switch Local Web page:
Make sure that your computer is on the same subnet with the switch (192.168.0.0/24) and directly connect to it with an RJ-45 cable.
Under your web browser, enter the URL: http://192.168.0.239 to access the Switch's local web interface.
You can review the device status after logging into the Switch with the default admin account/password (admin/password).
Check the information on the Dashboard and take action if necessary.
Change IP Assignment Settings
By default, the EnGenius Cloud Switch (ECS series) is assigned an IP address dynamically by the DHCP server. If you encounter issues with IP address assignment, please double-check the IP setting, including IP address, subnet mask, gateway, DNS, and management VLAN. If the issue still exists, you may change your IP assignment from "DHCP " to "Static" via the following procedure.
Go to the Configure> System Settings> IP Address Settings section.
Change Configuration setting to "Static".
Configure the IP address, gateway, subnet mask, and DNS settings.
Reconnect this Switch to the LAN network and try again
Los Angeles, USA
Canada
Netherlands
Dubai, UAE
Local: (+971) 4 339 1227
Singapore
Local: (+65) 6227 1088
Taiwan, R.O.C