Only this pageAll pages
Powered by GitBook
1 of 10

EXT1105P QSG

Loading...

Loading...

Loading...

Loading...

Loading...

Appendix

Loading...

Loading...

Loading...

Loading...

Disclaimer/ Note

  • Maximum data rates are based on the IEEE standards. Actual throughput and range may vary depending on many factors including environmental conditions, the distance between devices, radio interference in the operating environment, and the mix of devices in the network.

  • Features and specifications are subject to change without notice.

  • This device complies with Part 15 of the FCC Rules.

  • Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

  • Trademarks and registered trademarks are the property of their respective owners. For the United States of America: Copyright © 2023 EnGenius Technologies, Inc. All rights reserved.

Switch Extender 4 PoE

4x GE PoE and 1x GE PD Switch Extender

Introduction

This Quick Start Guide is designed to guide you through the installation of the Switch Extender 4 PoE, model EXT1105P, including hardware mounting and configuration.

Extender 4 PoE

4x GE PoE and 1x GE PD Switch Extender

Model: EXT1105P

NOTICE:

To prevent abnormal PoE output from the Switch Extender, make sure to use a standard PoE power supply compliant with 802.3at or 802.3bt.

EXT1105P supports those PoE power supply methods

Power Input and Power Budget about EXT1105P

  • Power Input: 802.3at Type 2 (30W); Power Budget: up to 15W

  • Power Input: 802.3bt Type 3 (60W); Power Budget: up to 40W

Content Quick Links

Package Contents

System Requirements

Web Browser:

  • Google Chrome (57.0.2987.110 and later)

  • Microsoft Edge (80.0.361.103 and later)

  • Mozilla Firefox (52.0 and later)

Hardware Overview

Front Panel - Ports & Buttons

  • Reset to default: Press and hold for over 10 seconds, and all ports LED will go off and on. Then the device will be reset to factory default settings.

  • Change LED display mode: Press the button to change the LED mode to display the PoE status of PoE-abled ports.

Front Panel - System & Ports LEDs

Cloud Management - FitXpress

Configure with EnGenius FitXpress

Step 1: Connecting to Ethernet

Connect the Ethernet cable from the EnGenius Switch Extender directly to the DHCP-enabled network

Declaration of Conformity

Hereby, EnGenius Networks declare that this product is in compliance with:

  • Directives 2004/108 EC (EMC); 2014/30/EU (EMC); 2006/95/EC (LVD); 2014/35/EU (LVD)

  • RoHS Directive 2015/863

  • WEEE Directive 2012/19/EU

Management Plane

Management Plane

EnGenius Cloud provides flexibility to manage your devices based on your network planning and deployment.

Option A: EnGenius Cloud To-Go

Option A: EnGenius FitXpress

REACH Regulation

4 x 1G PoE+ Ports to unleash elevated speeds for IP Camera, wireless AP or VoIP Phone

  • 1 x 1G PoE++ PD ports for PoE power input

  • 60w PoE adapter EPA5060GBT (selective purchasing)
  • 90w PoE adapter EPA5090GBT (selective purchasing)

  • 90W is the maximum power input that EXT1105P can support

  • We strongly recommend using EnGenius PoE adapters (EPA5060GBT, EPA5090GBT) and the power adapter. We are not responsible for any hardware abnormalities caused by power supply issues that are not related to the equipment mentioned above.

    Power Input: 802.3bt Type 4 (90W); Power Budget: up to 60W
    Switch
    Hardware Overview
    Hardware Installation
    Configure with EnGenius Cloud
    Package Contents
    and make sure the switch can reach the Internet.

    Step 2: Register Device

    You can register the switch with the FitXpress app.

    1. Open the FitXpress mobile app and create an account.

    2. Log in and go to the Devices section. Click the Add(+) button.

    3. Scan the QR code on the back of the device via the app.

    *The display model number may be varied according to different models.

    4. If the camera successfully scans a QR code, the app will display the device Information. You could tap "Register" to complete the registration.

    *The display model number may be varied according to different models.

    Step 3: Connect to the FitXpress

    Once the device is powered on and ready to connect to the Internet, the PWR LED will stay Solid On, which means the device is now connected to the FitXpress platform. It will automatically download the default configuration settings from FitXpress for automated provisioning.

    When the switch is connected to the FitXpress platform for the first time, it will automatically check the latest available firmware. If the firmware upgrade is required, it might take 8~10 minutes to complete the process

    Step 4: Manage with FitXpress

    Log in to the FitXpress app to configure detailed settings and monitor your devices.

    *The display model number may be varied according to different models.

    Change the Management Plane

    If you want to manage your device through another cloud mmanagement, please unregister your Switch Extender device on FitXpress first. Then, register the device on Cloud To-Go. You can follow the steps below to deregister a device.

    • Navigate to the device page.

    • Select your Switch Extender device on Switch Extender page.

    • Click "Delete Device" to delete Switch Extender on device page.

    • Press the reset button for 10 seconds to return the device to its default settings.

    • Follow the instructions to register the Switch Extender.

    Cloud Management - Cloud To-Go

    Manage and monitor the switch through the EnGenius Cloud To-Go with a mobile app or through the web portal.

    ⬇️ Download the Cloud To-Go mobile app here

    Cloud Management - FitXpress

    Manage and monitor the switch through the FitXpress Platform with a mobile app or through the web portal.

    ⬇️ Download the FitXpress mobile app here

    Cloud Management - Cloud To-Go

    Hardware Installation

    Hardware Installation

    The EXT1105P can be mounted on the wall. Please perform the steps to install:

    Place on a Flat Surface

    Attach the Rubber Footpads at the bottom of the Switch Extender at each corner. The Rubber Footpads help secure the Switch Extender and protect it from vibration and shock when stacking.

    Wall Mount

    1. Determine where the Switch Extender will be placed and mark the location on the surface for the two mounting holes. Use the appropriate drill bit to drill two 8.1mm diagram and 26mm-deep holes on the marks.

    2. For easy installation, it is recommended to use the adhesive label inside the Package Content to confirm the screw hole positions.

    3. Screw the Anchors into the holes until they are flush with the wall; screw the included Screws into the Anchors but leave the screw head sticking out so you can hang the Switch Extender on it.

    4. Place Switch Extender against the wall onto the Screw heads.

    Technical Support

    Country of Purchase
    Service Center
    Service Information

    Cloud Management - Cloud To-Go

    Configure with EnGenius Cloud To-Go

    Step 1: Register Device

    *The display model may be varied according to different models.

    Dubai, UAE

    Local: (+971) 4 339 1227

    Singapore

    Local: (+65) 6227 1088

    Taiwan, R.O.C

    North America

    Los Angeles, USA

    cloud.engenius.ai

    [email protected]

    North America

    Canada

    cloud.engenius.ai

    [email protected]

    Europe

    Netherlands

    You can register the device either by
    Cloud To-Go
    mobile app
    or
    the
    EnGenius Cloud platform.

    Cloud To-Go Mobile App

    You can register the switch with the Cloud To-Go app.

    1. Open and log in to the EnGenius Cloud To-Go mobile app.

    2. Scan the QR code on the back of the device via the app

    *The display model number may be varied according to different models.

    3. If the camera successfully scans a QR code, the app will display the Device Information. You could tap "Register" to complete the Registration.

    4. Registered devices will be shown on the Inventory&License page. Slide left the device and click "Add to Network" add the device to your personalized Network.

    *The display model number may be varied according to different models.

    Network: Management domain shared same configurations within EnGenius Cloud.

    EnGenius Cloud Platform

    1. Login into the EnGenius Cloud Platform: https://cloud.engenius.ai/

    2. Go to the home > Inventory page and click "Register Device".

    3. Enter the Serial Number of the device(s) for device registration. Please refer to "User Manual-Registering Devices to Organization".

    4. Select the registered device and click "Assign to Network" to add the device to your personalized Network.

    Network: Management domain shared same configurations within EnGenius Cloud.

    Step 2: Connect to EnGenius Cloud

    Log in to the EnGenius Cloud Platform to configure detailed settings. For more information, please refer to User Manual.

    EnGenius Cloud Connected

    Once the device is powered on and ready to connect to the Internet, It will automatically download the default configuration settings from EnGenius Cloud for automated provisioning.

    When the Switch is connected to the EnGenius Cloud Platform for the first time, it will automatically check the latest available firmware. If the firmware upgrade is required, it might take 8~10 minutes to complete the process.

    Step 3: Manage with the EnGenius Cloud

    Log in to the EnGenius Cloud Platform to configure detailed settings. For more information, please refer to User Manual.

    *The display model number may be varied according to different models.

    Troubleshooting

    If your Switch cannot be managed by the EnGenius Cloud Platform, there might be a problem with connecting to EnGenius Cloud.

    To troubleshoot the connection issue, you may log in to the Local Status page:

    1. Ensure your computer is on the same subnet with the switch (192.168.0.0/24) and directly connect to it with an RJ-45 cable.

    2. Under your web browser, enter the URL: http://192.168.0.239 to access the Switch's local web interface.

    3. You can review the device status after logging into the Switch with the default admin account/password (admin/password).

    4. Check the information on the MONITOR and take action if necessary.

    *The display model number may be varied according to different models. be varied according to different models.

    Change IP Assignment Settings

    By default, the EnGenius Cloud Switch (ECS series) is assigned an IP address dynamically by the DHCP server. If you encounter issues with IP address assignment, please double-check the IP setting, including IP address, subnet mask, gateway, DNS, and management VLAN. If the issue still exists, you may change your IP assignment from "DHCP " to "Static" via the following procedure.

    1. Go to the Configure> Local Settings section.

    2. Change the Configuration setting to "Use Static IP".

    3. Configure the IP address, gateway, subnet mask, and DNS settings.

    4. Reconnect this Switch to the LAN network and try again.

    Change the Management Plane

    If you want to manage your device through FitXpress, please unregister your Switch Extender device on Cloud platform first. Then, register the device on FitXpress. You can follow the steps below to deregister a device.

    • Navigate to the Switch Extender page.

    • Select your Switch Extender device.

    • Click "Remove from Network" to delete Switch Extender device on Switch Extender device page.

    • Go to "Inventory & License".

    • Select your Switch Extender device on "Inventory & License" page.

    • Click "De-Register Device" on "Inventory & License" page to delete Switch Extender device.

    • Press the reset button for 10 seconds to return the device to its default settings.

    • Follow the instructions to register the Switch Extender.

    Compliance

    FCC

    This device complies with Part 15 of FCC rules. Operation is subject to the following two conditions:

    (1) This device may not cause harmful interference.

    (2) This device must accept any interference received, including interference that may cause undesired operations.

    WARNING!

    Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.

    This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his/her own expense.

    CE

    This device complies with the essential requirements and other relevant provisions of the directives 2004/108 / EC (EMC); 2014 / 30 / EU (EMC); 2006/95 / EC (LVD); 2014/35 / EU (LVD). The following test methods have been applied in order to prove the presumption of conformity with the essential requirements:

    • EN 55035: 2017/A11:2020

    • EN 55032:2015+AC:2016, Class A

    • EN 55024:2010+A1:2015

    • EN 61000-3-2:2014

    • EN 61000-3-3:2013

    • EN 61000-4-2:2008

    • EN 61000-4-3:2006 +A1:2008 +A2:2010

    • EN 61000-4-4:2012

    • EN 61000-4-5:2014 / AMD1:2017

    • EN 61000-4-6:2013

    • EN 61000-4-8:2009

    • EN 61000-4-11:2004 / AMD1: 2017

    • EN 62368-1:2014+A11:2017

    NOTICE:

    The operation of this equipment in a residential environment may cause radio interference.

    IC

    The following information applies if you use the product within Canada.

    Industry Canada ICES Statement:

    • CAN ICES-003 (Issue 6)

    [email protected]
    Africa / CIS / Middle East
    [email protected]
    Asia / Oceania
    [email protected]
    Taiwan
    [email protected]
    Cloud Management - FitXpress